INSTRUCTION MANUAL FOR K-PATENTS PR-01-S (-AX/FM/CS)

DOCUMENT/REVISION No. INM 1/14

Effective: May 15, 2009

16

2.10. IT-R PROGRAM VERSIONS

The program version number consists of two digits. The first digit is the major version, the latter is the minor
version. Programs with the same major versions are compatible. Also earlier major versions can usually be
substituted with later major versions.

Version 1.0

Version 2.0: Supports external output unit, Section 10.1. Revised calculation of Standard RI (25 °C), new
style constants. Addition of standard RI to serial output data.

Version 2.1:External output is set inactive by setting the output range span to 0.

Version 3.0: Language selection English/German. Up-date of the optional Standard RI (25 °C) display.

Version 3.1: The measuring task has a higher priority than the keyboard handling task. The default for
relay alarm delay is changed from 0 to 10 s.

Version 4.0: Supports K-Patents Divert Control unit DD-01. Password protection added, Section 2.11. The
RI display is shown without the reference temperature, if both temperature coefficient values for RI are
zero.

Version 5.0: This version is accompanied by a a sensor modification: The PLUG-IN LIGHT SOURCE,
eliminating the light source module adjustments to the optical image. The PLUG-IN LIGHT SOURCE
should not be used with any lower program version. Program version 5.0 is compatible with all PR-01-S
sensors.
The range of the TEST display is now limited to 8...248. An advanced image analyzing algorithm is
implemented, Figure 2.52 including IMAGE DIAGNOSTICS screen (Section 6.5). BRIX unit added
(Section 2.8). The current output parameters ICAL0 and ICAL1 added to the current output calibration
screen. Password limit moved (Figure 2.61): Raw data + Optical image available without password.

Version 6.0: Switch inputs for external wash stop and calibration stop added, Section 2.8. Wash stop when
the process temperature is below the limit added, Section 9.2. Limit to divert alarms added (Ref. difference
max 2% , Solids alarm min. 58%, Solids warning min 60%). Output unit Oe (Oechsle) added, Section 5.2.
Temperature filtering of Intrinsically safe sensor is changed. Support for small relay unit added. Internal
Sensor humidity and temperature added.

Version 6.2: A check for Relay accessibility is added to wash check logic. Support to read the display
memory is added to the display driver and the display manager modules.

Version 7.0: Support for built-in signal relays on power supply card, Section 2.5. New relay signal
sources: internal sensor temperature and internal sensor humidity, Section 9.2. Change of error
classifications, Section 6.3. Display timeouts, Section 2.6.

Version 8.1: Support for Sanitary Refractometer PR-03-A. Smart Wash for prism wash, Section 9.4.

Version 8.2: Improved image handling.

Version 8.3: Changes in diagnostics message classification. Change in serial output timing.

Version 8.4: Maximum wash time decreased from 60s to 30s.

Version 8.5: Change in relay configuration. Change in unit marking on main display.

Version 8.6: Support for Sanitary Probe Refractometer PR-03-P

Version 8.7: Support for optical image of Sanitary Probe Refractometer PR-03-P.