ID

Description

Details

7210

Open contact - circula-

tion temp. probe S05

Open contact - drinking water circulation temperature probe

7211

Short circuit - circula-

tion temp. probe S05

Short circuit - drinking water circulation temperature probe

7212

Open contact - inlet

temp. probe S13

Open contact - inlet temp. probe

7213

Short circuit - inlet

temp. probe S13

Short circuit - inlet temp. probe

7218

Open contact - collector

1 probe S01

Open contact - collector 1 probe

7219

Short circuit - collector

1 probe S01

Short circuit - collector 1 probe

7236

Open contact - mix.

heating circuit inlet

temp. probe S12

Open contact - mixed heating circuit inlet temperature probe

7237

Short circuit - mix.

heating circuit inlet

temp. probe S12

Short circuit - mixed heating circuit inlet temperature probe

7238

Open contact - mix.

heating circuit return

temp. probe S11

Open contact - mixed heating circuit return temperature probe

7239

Short circuit - mix.

heating circuit return

temp. probe S11

Short circuit - mixed heating circuit return temperature probe

7250

Min. medium flow rate

The medium flow rate fell below the heat generator's minimum medium

flow rate

7251

Min. medium flow rate

The medium flow rate fell below the heat pump's minimum medium flow

rate due to defrosting or in cooling mode. After eliminating the cause of

the error, the controller must be restarted to reset the error.

7252

Heat pump alarm code

S20

Heat pump alarm code

7276

Restart required

Due to the changed system (setting / coding resistor), the controller has

to be restarted - disconnect it from the power supply for around 10 sec-

onds.

7283

Open contact - WE

return temp. probe S15 Open contact - WE return temperature probe

7284

Short circuit - WE

return temp. probe S15 Short circuit - WE return temperature probe

7286

Rc coding error

A unique unit identifier could not be assigned using the coding resistor at

the Rc terminal.

7333

Negative temp. differ-

ence

The temperature difference when the heat generator is active is implau-

sible

REMKO WKF Duo

52