Setup menu chart – Tascam MMR-8 User Manual

Page 91

Advertising
background image

MMR-8

TASCAM MMR-8 Owner’s Manual • Chapter 6 • File Format Support

91

Setup Menu Chart

The following chart shows all MMR-8 Setup menus and parameters, Note that * indicates the default
selection.

MENU #

MENU NAME

PARAMETERS

000

Control Mode

Local/MMR*
Time Code Chase
Biphase Chase
Serial Transport
Editor
Varispeed

001

Frame Reference

Automatic*
Video

002

Sample Reference

Automatic*
AES/EBU Input
Ext Wordclock

003

Time Code Type

24/24
25/25
29.97/DF
29.97/NDF
30/DF
30/NDF*

004

Sample Rate

42294 (44x23/25)
42336 (44x24/25)
44056 (44100-)
44100
44144 (44100+)
45938 (44x25/24)
45983 (44x25/23)
46034 (48x23/25)
46080 (48x24/25)
47952 (48000-)
48000*
48048 (48000+)
50000 (48x25/24)
50050 (48x25/23)

006

Varispeed Rate

100% *
(range 88.5% to 104.3%)

100

Sync Group

1*
2
3
4