S e c u r e C o n s o l e S e r v e r M a n u a l , R e v . K , J u l y , 2 0 1 3

Page 22

The default communication parameters for the server Ports are:

••••

9600 baud

••••

8 data bits

••••

No parity

••••

1 stop bit

••••

Xon/Xoff flow control

••••

DCE Port type

Each Port can be individually configured for baud rates of 300-115K for specified data
parameters and as DTE or DCE types.

!

Note: Ports may also be individually disabled if desired.

3.2.5.1 Automated Port Configuration Tests

A script named

pm

is available to test the device ports and report the correct DTE/DCE

setting for each port. A

man

page exists for

pm

. This can be used to troubleshoot SCS to

server connections. Hardware signals from the server are tested but Baud rates are not.

3.2.5.2 Port Adapters

You may need to adapt the cable connection for your server device. Thinklogical

®

offers serial-

to-RJ45 adapters for serial ports, both DB9 and DB25, for many common network-equipment
product applications. See Appendix F on page 85 for more information.

3.2.5.3 Serial Port Pin-out

Serial Port pin-out