S-registers – Thinklogical Secure Console Server Manual User Manual

Page 79

Advertising
background image

S e c u r e C o n s o l e S e r v e r M a n u a l , R e v . K , J u l y , 2 0 1 3

Page 79

#CBS1

Enables local and remote callback security.

#CBS2

Enables remote callback security only.

#CBS3

Disables callback security until local hangup or reset.

Command:

#Pn

Set 11-bit Parity

Values:

n = 0 or 1

Default:

2

Description:

#P0

No parity.

#P1

Odd parity.

#P2

Even parity.

Command:

#Sx

Enter Setup Password

Values:

x= password (1–8 characters, case sensitive)

Default:

MTSMODEM

Description:

Enters the callback security setup password.

Command:

#S=x

Store Setup Password

Values:

x= password (1–8 characters, case sensitive)

Default:

MTSMODEM

Description:

Stores a new callback security and remote configuration setup password.

S-Registers

Certain modem values, or parameters, are stored in memory locations called S-Registers. Use
the S command to read or to alter the contents of S-Registers (see previous section).

Register

Unit

Range

Default

Description

S0

1 ring

0, 1–255

1

Sets the number of rings until the modem answers. ATS0=0 disables auto

answer completely.

S1

1 ring

0–255

0

Counts the rings

that have occurred.

S2

decimal

0–127

43 (+)

Sets ASCII code for the escape sequence character.

128–255

Values greater than 127 disable escape.

S3

decimal

0–127

13 (^M)

Sets the ASCII code for the carriage return character.

S4

decimal

0–127

10 (^J)

Sets the ASCII code for the line feed character.

S5

decimal

0–32

8 (^H)

Sets the ASCII code for the backspace character.

33–1 27

Values greater than 32 disable backspace.

S6

seconds

2–65*

2*

Sets the time the modem waits after it goes off-hook before it begins to dial the

telephone number.

S7

seconds

35-65*

50*

Sets the time the modem waits for a carrier signal before aborting a call. Also

sets the wait for silence time for the @ dial modifier.

S8

seconds

0–65

2

Sets the length of a pause caused by a comma character in a dialing com-

mand.

S9

decimal

0, 1–127

37 (%)

Sets ASCII code for remote configuration escape character. S9=0 disables

remote configuration.

S10

100 ms

1–254

20

Sets how long a carrier signal must be lost before the modem disconnects.

S11

1 ms

50–1 50*

95*

Sets spacing and duration of dialing tones.

S28

decimal

0, 1–255

1

0 disables, 1–255 enables V.34 modulation.

S30

1 minute

0, 1–255

0

Sets the length of time that the modem waits before disconnecting when no
data is sent or received. A value of zero disables the timer. See also the \T

command

S35

decimal

0–1

1

0 disables, 1 enables the V.25 calling tone, which allows remote data/fax/voice

discrimination.

S36

decimal

0–7

7

Specifies the action to take in the event of a negotiation failure when error control

is selected. (See S48.)

S37

decimal

0–19

0

Sets the maximum V.34 “upstream” speed at which the modem attempts to

connect.

Advertising