PCI Modem Card User's Manual

56

rate have been determined and before any error control or data compression

reports or the final result code (e.g., CONNECT) is transmitted.

+MR=0

Enables the modulation report (default).

+MR=1

Disables the modulation report.

+MS=<carrier>,<automode>,<min_rate>,<max_rate>—Modulation

Selection
Use this command to set the modem’s modulation, the modulation’s
minimum and maximum transmission rate, and the status of automatic
modulation negotiation (automode). The <carrier>, <min_rate>, and
<max_rate> parameters define the modulation and its minimum and

maximum rates.

The <automode> parameter enables or disables automatic modulation
negotiation. If a subsequent +MA command is not provided, the automode

parameters are constrained by the modulation set by the <carrier> parameter.

The +MA command can further restrict the automatic modulation
negotiation settings but it cannot set a modulation that is higher than the

modulation set by the +MS command.

Valid <carrier> Values:

V92

V.92 (default)

V90

V.90

V34

V.34

V32T

V.32ter

V32B

V.32 bis

V32

V.32

V22B

V.22 bis

V. 2 2

V. 2 2

Bell212A

Bell 212A*

V23C

V.23, constant carrier, asymmetric FDM

V21

V21

Bell103

Bell 103

Automatic modulation negotiation is enabled or disabled by <automode>.
However, if a value is specified for the <max_rate>, then automatic rate
selection is disabled and the modem will attempt to connect at the specified

rate.

Valid <automode> Values:
0

Disables.

1

Enabled (default).