Airlink AML001 User Manual

Page 58

Advertising
background image

Appendix A AT Commands

57

The <max_rate> specifies the highest connections rate for the DCE.

Valid <max_rate> Range:
0

Determined by modulation selected in <carrier> (default).

300—57333 Value limited by modulation selected in <carrier>.

Valid <max_rate> for each <carrier>:
V34

2400 bits/s—33600 bits/s in steps of 2400 bits/s.

V32bis

4800 bits/s—19200 bits/s in steps of 2400 bits/s.

V32

4800 bits/s—14400 bits/s in steps of 2400 bits/s.

V22bis

2400 bits/s.

V22

2200 bits/s.

V23C, Bell212A

1200 bits/s.

V.21, Bell103

300 bits/s.

+MSC=<src_v34>—Seamless Rate Change Enable
Use this command to enable or disable V.34 seamless rate changes.

+MSC=0

Disables V.34 seamless rate change.

+MSC=1

Enables V.34 seamless rate change (default).

+PCW=<call_waiting>—Call Waiting Enable
Use this command to select how the modem responds to a call waiting signal.
The soft modems response is also dependent on the current setting of the

caller ID command, +VCID.

Valid <call_waiting> Values:

0

Enable the call waiting detector. When a call waiting signal is
detected, toggle V.24 circuit 125 and collect caller ID as set by

+VCID (default).

1

Enable the call waiting detector. When a call waiting signal is

detected, hang up the current call.

2

Disable call waiting detector.

+PIG=<value>—PCM Upstream Ignore
Use this command to enable or disable PCM upstream in a V.92 connection.

+PIG=0

Enable PCM upstream.

+PIG=1

Disable PCM upstream (default).