Hot swappable poe module failure – H3C Technologies H3C S5800 Series Switches User Manual

Page 100

Advertising
background image

90

For more information about the LEDs on the OAP card, see H3C OAP Cards User Manual.

The OAP card LED (SLOT3) is steady green while the OAP card is correctly operating. If the LED behaves
in any other way, verify the following items:

The OAP card is compatible with the switch and can be installed in the OAP card slot.

The OAP card is correctly installed and well seated in the slot.

NOTE:

If the problem persists, contact your local sales agent or service engineer.

To replace the OAP card in the OAP card slot, see "

Removing the card in the OAP card slot (only for the

S5800-60C-PWR)

" and "

Installing an OAP card in the OAP card slot (only for the S5800-60C-PWR)

."

Failure of the OAP card in an expansion interface card slot

This section applies to all S5800 switches but the S5800-54S.
You can use the LEDs on the OAP card to identify its operating status. For more information about the

LEDs, see the user manual that comes with the card. If your switch has a status LED for the expansion

interface card slot, you can also use the LED to identify the operating status of the card.
If the OAP card is not correctly operating, verify the following items:

The OAP card is compatible with the switch and can be installed in an expansion interface card
slot.

The OAP card is correctly installed and well seated in the slot.

NOTE:

If the problem persists, contact your local H3C sales agent or service engineer for help.

To replace the OAP card in an expansion interface card slot, see "

Removing the OAP card in an

expansion interface card slot (for the entire series but the S5800-54S)

" and "

Installing an OAP card in

an expansion interface card slot (for the entire series but the S5800-54S)

."

Hot swappable PoE module failure

This section applies to the S5800-60C-PWR switch.
You can look at the SLOT4 LED on the front panel of the switch for a PoE module failure, as described

in

Table 22

.

The SLOT4 LED is steady green when the PoE module is functioning correctly. If the LED behaves in any

other way, check that:

The switch supports the PoE module model.

The PoE module is correctly installed and well seated in the switch.

NOTE:

If the problem persists, contact your H3C sales agent or service engineer for help.

To replace a PoE module, see "

Installing/Removing a PoE module

."

Advertising