9 turn encoder power supply on (sens_on: 23h), 9 turn encoder power supply on (sens_on: 23h) -17, 1) sens_on command (23h) – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 48

Advertising
background image

3.2 Commands Details

3-17

3

Commands for Preparation Process

3.2.9 Turn Encoder Power Supply ON (SENS_ON: 23H)

Send SENS_ON command to turn ON the encoder power supply.

(1) SENS_ON Command (23H)

The specifications of the SENS_ON command are described below.

(2) Monitor Selection Field Specifications: SEL_MON1/2/3/4

The monitor selection (SEL_MON1/2/3/4) field is used to select the Servo monitor information.

• Applicable Commands:

SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,

TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD_ON, LTMOD_OFF

• Setting Method:

Set MONITOR 1/2/3/4 monitor codes in SEL_MON1/2/3/4 allocated in the thirteenth byte of the main com-
mand or in the reserved area of the nineteenth byte of the subcommand.

SEL_MON1/2/3/4 allocation is shown below.

Byte

SENS_ON

Description

Command

Response

1

23H

23H

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous

command

2

ALARM

Processing

time

Within 2 s

Subcommand

Cannot be used

3

STATUS

• Obtains the initial position data and creates the present position when an

absolute encoder is used.

• The reference point, home position (ZPOINT), and software limits will

be enabled when an absolute encoder is used.

• After having used this command, the position data must be monitored

and the coordinate system of host controller must be setup.

4

5

MONITOR1

6

7

8

9

MONITOR2

10

11

12

13

SEL_MON1/2 SEL_MON1/2

14

IO_MON

15

16

WDT

RWDT

D7

D6

D5

D4

D3

D2

D1

D0

SEL_MON2

SEL_MON1

D7

D6

D5

D4

D3

D2

D1

D0

SEL_MON4

SEL_MON3