3 Commands for Preparation Process

3.2.12 Turn Servo OFF (SV_OFF: 32H)

3-24

3.2.12 Turn Servo OFF (SV_OFF: 32H)

Send an SV_OFF command to stop current flow through the servomotor.

(1) SV_OFF Command (32H)

The specifications of the SV_OFF command are described below.

Byte

SV_OFF

Description

Command

Response

1

32H

32H

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous

command

2

ALARM

Processing

time

The time set in
Pn506

(500 ms max.)

Subcommand

Can be used

3

STATUS

• Stops current flow through the servomotor.
• When Pn829 (SVOFF waiting time at deceleration to stop) is set to a

value other than 0, the servo will be turned OFF after the servomotor
decelerates to a stop according to the deceleration constant for stopping
set by the parameter. (The servomotor decelerates to a stop in position
control mode.)

• When Pn829 (SVOFF waiting time at deceleration to a stop) is set to 0,

the servo will be turned OFF immediately after reception of this com-
mand.

(The control mode before receiving SV_OFF command remains

unchanged.)

• Executing the SV_OFF command will cancel the speed reference, speed

feed forward, torque (force) feed forward, and torque (force) limits set by
a position/speed control command.