20 (2) operation, 3) related parameters – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 85

Advertising
background image

4 Motion Commands for Operation

4.2.9 Homing (ZRET: 3AH)

4-20

(2) Operation

The motion executed by ZRET command is illustrated below.

(3) Related Parameters

The parameters related to ZRET command are listed below.

Parameter number in parentheses is when Pn833 = 1.

∗1. The value of Pn842 is effective only when the value of Pn817 is 0.

∗2. The value of Pn844 is effective only when the value of Pn818 is 0.

Set the parameters as shown below to use TLIM.

Latch signal

DEC

Reference speed

Homing Approach Speed 1 (Pn817 or Pn842)

Homing Approach Speed 2 (Pn818 or Pn844)

Final Travel Distance for Homing (Pn819)

Parameter No.

Name

Parameter No.

Name

Pn816

Homing Direction

Pn002

Torque (Force) Reference Option during
Speed/Position Control

Pn817

Homing Approach Speed 1

*1

Pn80A (Pn834) 1st Linear Acceleration Constant

Pn842

Pn80B (Pn836) 2nd Linear Acceleration Constant

Pn818

Homing Approach Speed 2

*2

Pn80C (Pn838) Acceleration Constant Switching Speed

Pn844

Pn80D (Pn83A) 1st Linear Deceleration Constant

Pn819

Final Travel Distance for Homing

Pn80E (Pn83C) 2nd Linear Deceleration Constant

Pn820

Forward Latching Allowable Area

Pn80F (Pn83E) Deceleration Constant Switching Speed

Pn822

Reverse Latching Allowable Area

Pn81F

Position Control Command TLIM Func-
tion Allocation

Parameter

No.

Set Value

Meaning

Pn81F

n.††1†

Enables positive/negative torque (force) limit (TLIM).

Pn002

n.†††1

Pn81F

n.††1†

When P_CL of OPTION field is set to 1: Uses TLIM as positive torque (force) limit.
When N_CL of OPTION field is set to 1: Uses TLIM as negative torque (force) limit.

Pn002

n.†††3

Advertising