Device Diagnostics Utility

Operational check for the devices connected to the SR-600 is accomplished.

The device diagnostics utility can perform the following tests:

TM printer printing test

Customer display test

Cash drawer operation test

Serial port loop-back test

LPT1 port loop-back test

Printer connected to LPT1 printing test

Ethernet loop-back test

Conditions for Running Device Diagnostics

Device diagnostics utility is performed under the following conditions shown in the table.

Table 3-9 Conditions

Setting

Condition

Connection to the TM printer

The TM printer needs to be connected to

SR-600. Connect the

printer to either COM port or LPT1, even if you will not test the TM printer.

Setting of the TM printer DIP

switches

Set the receiving buffer to maximum. Set selection switch (customer display
connection / non-connection) to non-connection (if it has a selection
switch). Set the communication settings following the instructions, if the TM
printer does not have an ID function. (ESC/POS GS I command).
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
Refer to the TM printer manual for the setting procedure.

DM display connect port

Connect the DM display to DM display port, when the DM display is tested.

Setting of DIP switches for the DM
display

When the TM printer is connected to COM1:
Set the communication settings following the instructions, when the TM
printer has the ID function (ESC/POS GS I command).
Baud Rate: Same setting as for the TM printer (9600 bps)
Word Length: Same setting as for the TM printer (8 bits)
Parity: Same setting as for the TM printer (None)
Set the communication settings following the instructions, if the TM printer
does not have the ID function. (ESC/POS GS I command).
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
When the TM printer is connected to another port besides COM1:
Set the DM display communication settings following the instructions.
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
Refer to the DM display manual for the setting procedures.