Device test menu, Confidential – Epson SR-600 User Manual

Page 69

Advertising
background image

Rev.A

BIOS Setup 3-25

Developer's Guide SR-600

Confidential

Enable/ Disable the Ethernet Controller Boot-ROM(ROM)
Displays "Enable” in the normal operation and “Disable” in other situations.

Ethernet ID(ID)
Displays 12 digit hexadecimal numbers separated by hyphens. Only a hyphen is
displayed if there is no controller.

BIOS version (BIOS Version)

Keyboard Firmware Version (K/B Firmware Version)

Main Board Total Run Time (M/B Total Run Time)
Displays in hours. Maximum of 1193046 hours.

Battery Discharge
Rechargeable for a maximum of 65535 times.

Device Test Menu

The test for each devices can be performed from the Device Tests and More Tests menu. The
device test is explained below.

❏ TM print test

The following tests are run in the TM print test.

Print test for receipt paper (Standard print pattern)
Autocutter test (restricted to those printers with Autocutter)

When the test is completed, “TM print test:done” message appears on the message area.
Make sure that the print pattern is printed. And check that the receipt paper is cut by the
autocutter if the printer is equipped with an autocutter.
TM print test is not performed if the TM Status is Disable or No communication.

❏ DM display test

Sends following messages to the DM display.

Display Module Test
**** Device Diagnostics ****

Check the DM display and make sure that the test is performed.
Press any key to finish the test. The message “DM display test: done” appears on the
message area.
DM display test is not performed if the DM Status is Disable or No communication.

❏ Drawer kick out test

Drawer kick out test opens the cash drawer. Make sure that the cash drawer board opens
normally. TM printer has drawer kick out drive signal (Signal 1 and 2). This test is effective
only for drawer kick out drive signal 1.
If the password has been set for the drawer kick out test, it asks your password to run the
drawer kick out test.
Drawer kick out test is not performed if the DM Status is Disable or No communication.

❏ COM1/COM2/COM5/COM6 loop-back

Runs data transmission test of serial port. It performs data transmission to a target port,
therefore, it is required to connect a loop-back connector to the target port. COM port test

Advertising