4 technical data, 1 electrical data, Technical data – KACO Powador 10.0 - 20.0 TL3 User Manual

Page 10: Electrical data, 4technical data

Advertising
background image

EN

EN

Technical Data

Page 10

Operating Instructions Powador 12.0 TL3-20.0 TL3

4

Technical Data

4.1

Electrical data

Input levels

12.0 TL3

14.0 TL3

18.0 TL3

20.0 TL3

DC MPP range from [V] to [V]*

350 ... 800

350 ... 800

420 ... 800

460 ... 800

Operating range from [V] to [V]

200 ... 800

Starting voltage [V]*

250

Open circuit voltage [V]

1,000 (start up to 1,000)

Rated current max. [A]

2 x 18.6

Max. power per tracker [W]

10200

12800

12800

12800

Number of strings

2 x 2

Number of MPP controls

2

Polarity safeguard

Short-circuit diode

DC overvoltage safety class

III

DC overvoltage category

II

*At DC voltages below the MPP range the maximum rated current reduces the maximum input power.
**For PV generators with MPP voltages below the MPP range of the inverter: set the start voltage in the menu.

Output levels

12.0 TL3

14.0 TL3

18.0 TL3

20.0 TL3

Rated power [VA]

10000

12500

15000

17000

Grid voltage [V]

400/230 (3/N/PE)

Rated current [A]

3 x 14.5

3 x 18.1

3 x 21.8

3 x 24.6

Rated frequency [Hz]

50 / 60

cos phi

0.80 inductive to 0.80 capacitive

Number of feed-in phases

3

Distortion factor [%]

5.5

AC overvoltage safety class

III

AC overvoltage category

III

General electrical data

12.0 TL3

14.0 TL3

18.0 TL3

20.0 TL3

Max. efficiency [%]

98.0

98.0

98.0

97.9

European efficiency [%]

97.5

97.6

97.7

97.6

Make current [A] and ON duration [ms]

4.52 / 4.4

Internal consumption: night [W]

1.5

Feed-in starts at [W]

20

Circuit design

Transformerless

Grid monitoring

Country-specific

Advertising