Installing the inverter

Page 20

Operating Instructions Powador 12.0 TL3-20.0 TL3

Authorised electrician

7.2.2.3 Recommended standard connection

DANGER

Risk of fatal injury due to electric shock (electric arc)!
Wrong assignment of MPP trackers will seriously damage the inverter
Severe injury or death will result if the live connections are touched.

Make sure that each MPP tracker can be disconnected from all poles.

Observe recommended standard connection.

Equal MPP voltages must be applied to input 1 and 2, as well as inputs 3 and 4. The MPP voltages of the two DC

paths can be different. They are tracked by separate, independently operating MPP trackers (MPP trackers A and B).

(n

1

=n

2

, n

3

=n

4

).

Electrical data for standard connection

Connecting the DC inputs

Number of modules per string: n

1

=n

2

, n

3

=n

4

P

max

Per string < 0.5 * max. recommended PV generator power
MPP tracker A+B together < max. recommended PV generator power

I

max

Amperage per tracker < max. rated current (DC)

1

A

B

2

3

4

U

MPP

U

MPP

n

1

n

2

n

3

n

4

=

=

Figure 9: Recommended standard connection