Configuration and operation – KACO Powador 10.0 - 20.0 TL3 User Manual

Page 34

Advertising
background image

EN

EN

Configuration and Operation

Page 34

Operating Instructions Powador 12.0 TL3-20.0 TL3

Country-

spec. Setting

Menu

level

Display/settings

Action in this menu/meaning

0

1

2

3

2

Day display

Displays the recorded operating data graphically.
1. Select the measured value to be displayed.
Supported measured values:

Grid power P(grid)

DC power per string P(PV) 1-2

DC voltage per string U(PV) 1-2

Unit temperature

2. Select a day.
3. Press the OK button.

»

The display shows the selected data.

"

Press any button to return to the previous menu.

0

1

2

3

2

Month display

Displays the recorded operating data graphically.
1. Select a month.
2. Press the OK button.

»

The display shows the selected data.

"

Press any button to return to the previous menu.

0

1

2

3

2

Year display

Displays the recorded operating data graphically.
1. Select a year.
2. Press the OK button.

»

The display shows the selected data.

"

Press any button to return to the previous menu.

0

1

2

3

2

CSV log data

"

Open the menu: Press the right arrow button or

the OK button.

0

1

2

3

3

Decimal separator

"

Select decimal sign for export of saved operating

data.

0

1

2

3

3

Save to USB

In this menu, you can export the saved operating data

to a connected USB storage device.

↻ You have connected a USB storage device to the

inverter.

1. Select the data to be exported (year, month or day).
2. Press the OK button.

»

The inverter writes the data to a connected USB

storage device.

0

1

2

3

0

“Settings” menu

"

Open the menu: Press the right arrow button or

the OK button.

0

1

2

3

1

Language

"

Select the desired language for the user interface.

0

1

2

3

1

Def. total yield

You can set the total yield to any value, for example,

when you have received a replacement unit and want to

continue the recording from the present value.

"

Select the “Save” button and confirm with the OK

button.

0

1

2

3

1

Interface

"

If the inverter is a terminal unit: Activate termination

(“Bus termination” menu option)

"

Assign a unique RS485 bus address to the inverter

(“RS485 address” menu option). The address must

not be the same as that of any other inverter or

a proLOG unit.