12 pf roller, P90) – Epson Stylus TX100 User Manual

Page 90

Advertising
background image

Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300

Revision A

DISASSEMBLY/ASSEMBLY

Disassembling the Printer Mechanism

90

Confidential

4.5.12 PF Roller

† Parts/Components need to be removed in advance:

Scanner Stand/Cover Wire (

p 60

), Scanner Unit (

p 62

), Middle Housing (

p 63

)

Panel Unit (

p 64

), Main Board (

p 65

), EJ Roller/ EJ Frame Assy (

p 73

)

CR Motor/ Driven Pulley (

p 75

), Ink System (

p 77

), Main Frame(

p 84

)

† Removal procedure

1. Remove the screw and then remove the Cover Flashing.
2. Remove the PF Roller Assy from the Lower Housing.

Figure 4-88. Removing the PF Roller Assy

C A U T I O N

Be careful not to touch the coating part of the PF Roller with bare
hands or damage it to avoid degrading the print quality.

Cover Flashing

PF Roller Assy

SCREW M3x8 P-TITE

„ Before installing the PF Roller, align the groove of the PF Roller

Shaft with the rib of the Lower Housing. (See

Fig.4-89

.)

„ Install the Cover Flashing following the procedure below.

1. Insert the hook of the Cover Flashing through beneath the

PF Roller into the hole of the Lower Housing.

2. Align each groove on the ribs on the rear of the cover with

the ribs of the Lower Housing, and secure it with the screw.

Figure 4-89. Installing the Cover Flashing

A D J U S T M E N T

R E Q U I R E D

Whenever the PF Roller is removed/replaced, the required
adjustments must be carried out.

Chapter 5 “ ADJUSTMENT” (p.100)

Cover Flashing

PF Roller

Hole

Ribs on the rear of the Cover

Hook

Ribs on the rear of the Cover

Rib

Groove of the PF Roller Shaft

and rib of the Lower Housing