4 messages, Error/warning messages, 1 errors – Epson S5U1C63000A User Manual

Page 121

Advertising
background image

CHAPTER 6: HEX CONVERTER

S5U1C63000A MANUAL

EPSON

107

(S1C63 FAMILY ASSEMBLER PACKAGE)

6.4 Messages

The hex converter delivers all its messages via the Standard Output (stdout).

Start-up message

The hex converter outputs only the following message when it starts up.

Hex converter 63 Ver x.xx

Copyright (C) SEIKO EPSON CORP. 1998-2001

End message

The hex converter outputs the following messages to indicate which files have been created when it
ends normally.

Created hex file <FILE NAME>.HSA
Created hex file <FILE NAME>.LSA
Created hex file <FILE NAME>.CSA
Created error log file HX63.ERR

Hex conversion 0 error(s) 0 warning(s)

Usage output

If no file name was specified or an option was not specified correctly, the hex converter ends after
delivering the following message concerning the usage:

Usage: hx63 [options] <file names>

Options: -b Do not fill unused memory with 0xff

-e Output error log file (HX63.ERR)

-i Use Intel Hex format

-o <file name> Specify output file name

File names: Absolute object file (.ABS)

ICE parameter file (.PAR)

When error/warning occurs

If an error occurs, an error message will appear before the end message shows up.

Example:

Error : No ICE parameter file specified

Hex conversion 1 error(s) 0 warning(s)

In the case of an error, the hex converter ends without creating an output file.

If a warning is issued, a warning message will appear before the end message shows up.

Example:

Warning : Output file name conflict

Hex conversion 0 error(s) 1 warning(s)

In the case of a warning, the hex converter ends after creating the output files, but the result cannot be
guaranteed.

For details on errors and warnings, refer to Section 6.6 "Error/Warning Messages".