3 start-up messages, 4 hardware check at start-up, 3 [source] window 8.4.4 [data] window – Epson S5U1C63000A User Manual

Page 135

Advertising
background image

CHAPTER 8: DEBUGGER

S5U1C63000A MANUAL

EPSON

121

(S1C63 FAMILY ASSEMBLER PACKAGE)

8.3.3 Start-up Messages

When the debugger starts up, it outputs the following message in the [Command] window. (Refer to the
next section for details about windows.)

Debugger63 Ver x.xx Copyright SEIKO EPSON CORP. 1998-2001

Connecting COMx with xxxxx baud rate ... done

Parameter file name : xxxxxxxx.par

Version : xx

Chip name : 63xxx

CPU version : x.x

PRC board version : x.x

LCD board version : x.x

EXT board version : x.x

ICE hardware version : x.x

ICE software version : x.x

DIAG test : omitted

Map............................... done

Initialize........................ done

>

8.3.4 Hardware Check at Start-up

When the debugger is invoked, it first performs the tests and initializing operations described below.

(1) Testing connection of the ICE

Debugger db63 first checks to see that the ICE is connected to your system and that communication is
possible without any problems. The following message is displayed in the [Command] window.

During test

Connecting COMx with xxxxx baud rate ...

When terminated normally

Connecting COMx with xxxxx baud rate ... done

When an error is encountered

Connecting COMx with xxxxx baud rate ... failure

<error message>

The error message indicates that communication between the personal computer and the ICE is not
functioning properly. In this case, to verify the following:

• A standard RS-232C cable is used
• The COM port is correct
• The baud rates on both sides are matched
• The PRC board is correctly fitted in place
• The ICE's power is turned on
• The ICE remains reset

For the causes of errors, refer to Section 8.10, "Status/Error/Warning Messages".