Epson S5U1C63000A User Manual

Page 174

Advertising
background image

CHAPTER 8: DEBUGGER

160

EPSON

S5U1C63000A MANUAL

(S1C63 FAMILY ASSEMBLER PACKAGE)

Notes

• The a and as commands have the same function.

• The start address you specified must be within the range of the program memory area available with

each microcomputer model.
An error results if the input one is not a hexadecimal number or not a valid symbol.

Error : invalid value

(no such symbol / symbol type error)

An error results if the limit is exceeded.

Error : Address out of range, use 0-0xXXXX

• An error results if the input mnemonic is invalid for S1C63000.

Error : illegal mnemonic

• In guidance mode, the following keyboard inputs have special meaning:

"q

"

… Command is terminated. (finish inputting and start execution)

"^

"

… Return to previous address.

"

"

… Input is skipped. (keep current value)

If the maximum address of program memory is reached and gets a valid input other than "^

", the

command is terminated.

• When the contents of the program memory are modified using the a (as) command, the unassemble

contents of the [Source] window are updated immediately.

• Although the contents of the unassemble display are modified by rewriting code, those of source

display remain unchanged.

GUI utility

None

Advertising