(S1C63 FAMILY ASSEMBLER PACKAGE)

10.3.5 Operation Procedure

The following shows the basic operation procedure.

(1) Loading the device information definition file

First, select a device information definition file (s1c63xxx.ini) and load it.
Select [Device INI Select] from the [Tool] menu or click the [Device INI Select] button.

[Device INI Select] button

The dialog box shown below appears. Enter a file name including the path in the text box or select a
file by clicking the [Ref] button.

Click [OK], and the file is loaded. If the
specified file exists and there is no problem
with its contents, the set-up items in winsog
are initialized with the loaded device
information.
To stop loading the file, click [Cancel].

10.3.4 Option Selection Buttons

The following buttons are available in the option setup area.

OUTPUT Option buttons

These buttons select SEG pin output modes. These buttons are enabled when you click a SPEC cell in
[SEGMENT DECODE TABLE].

Selects LCD segment output.

Selects DC-complementary output.

Selects DC-Pch open-drain output.

Selects DC-Nch open-drain output.

Selects segment/common shared output.

[Delete] button

Clears one selected segment assignment.