Voltage signal, Input signal, Input signal 3-wire voltage transducer – Precision Digital PD6310 User Manual

Page 24

Advertising
background image

Model PD6210 & PD6310 Batch Controllers

Instruction Manual

24

The current input is protected against current overload by a resettable
fuse. The display may or may not show a fault condition depending on
the nature of the overload.
The fuse limits the current to a safe level when it detects a fault condi-
tion, and automatically resets itself when the fault condition is removed.

-

+

+

Voltage

Signal

mA+

P-

2

1

3

5

4

P+

V+

COM

INPUT SIGNAL

mA+

P-

2

1

3

5

4

P+

V+

COM

INPUT SIGNAL

3-Wire Voltage

Transducer

Signal

-

Figure 10: Voltage Input Connections

The controller is capable of accepting any voltage from -10 VDC to
+10 VDC.

Advertising