Disabling Password Protection

To disable the password protection, access the Password menu and
enter the correct password twice, as shown below. The controller is now
unprotected until a new password is entered.

Locd

0

00000

Locd

unLoc

Locd

reset

20.000

mA

Run Mode

Pass

Enter

Password

unLoc

Pass 1

Enter

Password


If the correct six-digit password is entered, the controller displays the
message unLoc (unlocked) and the protection is disabled until a new
password is programmed.
If the password entered is incorrect, the controller displays the message
Locd

(Locked) for about two seconds, and then it returns to Run Mode.

To try again, press Enter while the Locked message is displayed.

Did you forget the password?

The password may be disabled by entering a master password once. If you
are authorized to make changes, enter the master password 508655 to unlock
the controller.