1. :RUN

Command Format:
:RUN

Function Explanation:
The command initiates the oscilloscope to acquire waveform data according to its
current settings. Acquisition runs continuously until the oscilloscope receives
a :STOP command.



2. :STOP

Command Format:
:STOP

Function Explanation:
The command controls the oscilloscope to stop acquiring data. To restart the
acquisition, use the :RUN command.


3. :AUTO

Command Format:
:AUTO

Function Explanation:
The command controls the oscilloscope to evaluate all input waveforms
characteristics and set the optimum conditions to display the waveforms.


4. :HARDcopy

Command Format:
:HARDcopy

Function Explanation:
The command is to extract the current information on the screen and save the
bitmap into the U disc in the form of “HardCopyxxx.bmp”. (Note: this command
is unavailable in file system)