Command Systems

RIGOL

Programming Guide for DS1000E, DS1000D Series

2-41

5. :TRIGger:ALTernation<mode>:LEVel

Command Format:
:TRIGger:ALTernation<mode>:LEVel <value>
:TRIGger:ALTernation<mode>:LEVel?

Function Explanation:
The commands set and query the trigger level of the current channel. <mode>
could be :EDGE, :PULSe or :VIDEO. The range of <value> is - 6*Scale ~ +
6*Scale,Scale indicates the current vertical scale, the unit is V/div.

Returned Format:

The query returns the setting value of <value> in V.

Example:
:TRIG:ALT:EDGE:LEV 2 Setup the trigger level of the current channel as 2V.
:TRIG:ALT:EDGE:LEV?

The query returns 2.00e+00.



6. :TRIGger:ALTernation:EDGE:SLOPe

Command Format:
:TRIGger:ALTernation:EDGE:SLOPe <value>
:TRIGger:ALTernation:EDGE:SLOPe?

Function Explanation:
The commands set and query the current edge type. <value> could be POSitive
(rising edge) or NEGative (falling edge).

Returned Format:
The query returns POSITIVE or NEGATIVE.

Example:
:TRIG:ALT:EDGE:SLOP POS Setup the edge type.
:TRIG:ALT:EDGE:SLOP?

The query returns POSITIVE.



7. :TRIGger:ALTernation<mode>:MODE