RS-232: Null Modem Connection (No Hardware Handshaking)

This type of connection can be used to connect the radio to a computer or field
device communication port.

Note: If the serial device is configured with to use the CTS line, then a jumper is required between
the RTS and the CTS line on the radio connection.

RS-485

The RS-485 interface requires a single two or three wire cable. The Common
connection is optional and dependent on the RS-485 network. The cable required
for this interface is shown below:

Note: The red switch on the bottom of the RLX-IFHS radio allows you to specify whether the
termination resistors are external or Internal in regards to the radio’s RS-485/RS-422 connector.

Terminating resistors are generally not required on the RS-485 network, unless you are

experiencing communication problems that can be attributed to signal echoes or reflections. In this

case, try changing the settings for termination on the radio.