7 Initial use
ATTENTION!
Please make sure that the unit is
not
connected to a power sup-
ply when preparing for initial use.
Acclimatization
When relocating the compact flash unit from and to locations
with substantial temperature differences, place the unit in the
surroundings where it is to be used and leave it there for some
time. This prevents moisture build-up which can result in cree
-
ping currents.
Removing transport cap
The transport cap protects the flash tube and the glass safety
dome during transport or when the unit does not have a reflec
-
tor mounted.
Â
Press the locking mechanism of the reflector holder against
the spring tension until reaching the end stop.
Â
Pull out the transport cap straight from the holder.
ATTENTION!
Do not switch on the flash unit with the transport cap attached.
This could pose a fire hazard due to the heat development of
the modeling light.
Mounting/removing safety dome
ATTENTION!
Please make sure the flash tube or modeling light is not dama
-
ged during mounting/removing.
The safety dome snaps into place via three pre-installed
springs.
Â
Tilt the safety dome slightly and insert it into one of the three
springs.