Test flash, Flash readiness, Daily flash counter – Hensel Expert D 1000 Flash Kit User Manual

Page 21: Synchronization

Advertising
background image

User Manual Expert D 500/1000

21

HENSEL-VISIT GmbH & Co. KG

Test flash

The key

TEST

3

lets you trigger a test flash manually. Holding

down the key results in the fastest possible sequence of flashes.

Flash readiness

After switching the unit on, after flashing, and after adjusting

the flash output, flash readiness is indicated on a green LED

2

located above the

TEST

key

3

.

Daily flash counter

The number of flashes triggered since last resetting the counter

is displayed on the LED display

5

.

How to read the flash counter:

Â

Press the key

AUDIO 19

for one second.

The number of flashes is shown in display

5

.

The number range of the flash counter goes up to 999.

How to reset the daily flash counter:

Â

While in flash count mode, press the rotary encoder

16.

The display

5

is reset to 000.

Synchronization

Synchronization between compact flash unit and camera can

be optionally achieved via sync cord, the built-in slave, or a

built-in radio receiver.

Synchronization via cord

The compact flash unit is connected to the camera via sync

cord by connecting the 6.3 mm jack plug to the camera’s sync

socket.
The synchronization process uses the latest semiconductor tech

-

nology and warrants reliable triggering of the flash unit even

when older camera models with mechanical contacts are used.

The lower voltage of the sync plug ensures safe and reliable

operation, also with the use of modern digital cameras.