Error messages – Hensel Expert D 1000 Flash Kit User Manual

Page 37

Advertising
background image

User Manual Expert D 500/1000

37

HENSEL-VISIT GmbH & Co. KG

Error messages

In case of an error, an error code is shown in display

5

. In this

case proceed as follows:

Â

Switch off the unit.

Â

Wait a few seconds.

Â

Switch the unit on again.

If the error code persists, check if the problem can be remedied

according to the following list or contact customer service and

state the error code, see „13 Customer service points“ on page

39.

Unit does not flash.

If several units are on the set, the misfiring of individual units is

shown in the display.
Possible causes can be a spent flash tube or an internal equip

-

ment problem.

Â

You may need to replace the flash tube or send the unit in

for service.

This error message disappears on its own after a short period

of time.

Unit is overheated.

In case of this problem, the modeling light shuts off and the

unit stops flashing.
Possible causes can be extensive flashing, high ambient tempe

-

ratures with full modeling light, covered core ducts, unsuitable

reflectors or a defective fan (check by listening).

Â

Keep the unit switched on so that the fan continues to cool

the flash unit.

Remedy or improve the situation by switching off the mode

-

ling light.

The error message disappears once the unit has cooled off.