User Manual Expert D 500/1000

20

HENSEL-VISIT GmbH & Co. KG

Normal operation is resumed automatically 5 sec. after last

using any control key.

Note:

Turning off the modeling light during longer breaks conserves

energy and expands the operating life of the lamp.

Performance output adjustment

The rotary encoder

16

adjusts the flash output in steps of 0.1

f-stops over an output range of 8 f-stops.

• Turning it

clockwise

increases the output in steps of 0.1

f-stops.

• Turning it

counter-clockwise

reduces the output in steps of

0.1 f-stops.

The LED display

5

shows the selected performance output valu

-

es from 3.0 (lowest output) to 10 (maximum output).

When the performance output is reduced, the stored energy is

reduced via automatic power dump (

APD function

).

Note:

The power dump takes a moment. The flash readiness indica

-

tor

2

lights up to indicate restored flash readiness.

Flash Check

The

Expert D 500/1000

is equipped with a visual flash readi

-

ness indicator called Flash Check. When this function is acti

-

vated, the modeling light shuts off after flashing and turns on

again when the flash readiness is restored.
Activate or deactivate Flash Check with the

FC

key

1

.

Advertising