Performance output adjustment, Flash check – Hensel Expert D 1000 Flash Kit User Manual
Page 20
User Manual Expert D 500/1000
20
HENSEL-VISIT GmbH & Co. KG
Normal operation is resumed automatically 5 sec. after last
using any control key.
Note:
Turning off the modeling light during longer breaks conserves
energy and expands the operating life of the lamp.
Performance output adjustment
The rotary encoder
16
adjusts the flash output in steps of 0.1
f-stops over an output range of 8 f-stops.
• Turning it
clockwise
increases the output in steps of 0.1
f-stops.
• Turning it
counter-clockwise
reduces the output in steps of
0.1 f-stops.
The LED display
5
shows the selected performance output valu
-
es from 3.0 (lowest output) to 10 (maximum output).
When the performance output is reduced, the stored energy is
reduced via automatic power dump (
APD function
).
Note:
The power dump takes a moment. The flash readiness indica
-
tor
2
lights up to indicate restored flash readiness.
Flash Check
The
Expert D 500/1000
is equipped with a visual flash readi
-
ness indicator called Flash Check. When this function is acti
-
vated, the modeling light shuts off after flashing and turns on
again when the flash readiness is restored.
Activate or deactivate Flash Check with the
FC
key
1
.