8 Operation

Switch on/off

The main switch

6

switches the compact flash unit on or off. The

unit is ready to flash as soon as the ready indicator

2

lights up.

ATTENTION!

The power switch must be accessible and operational at all

times.

When turning on the unit, it defaults to the settings used last.

This means the unit „remembers“ the settings at switch-off.

Modeling light

The modeling light is switched on by using the key

PROP 4

or the

key

FULL 17

. An LED above the key indicates the setting.

FULL

: The modeling light is set at full power (300 W).

PROP

: The light output (brightness) of the modeling light is pro-

portional to the flash output.

Automatic modeling light reduction (Autored)

The compact flash unit’s modeling light is equipped with an

energy saving mode. After a preselected time, the light is

automatically reduced to level 9. When set on FULL mode, this

happens regardless of the selected flash output. When set on

PROP mode, this happens when the output setting is between

9.1 and 10. The default is set by the manufacturer at 35 min.

This conserves energy and extends the lamp’s operating life.

The original output is restored when you touch any key.

How to set the switch-off time:

Â

Press the digital rotary encoder

16

twice in fast sequence

(double-click).

The display

5

shows the selected switch-off time for ca. 3 s.,

e.g. A.35

Â

Adjust the time by turning the rotary encoder

16

in 1 minute

increments up to a maximum of 90 minutes.

A setting of „

--

“ causes the function to switch off.