12 Maintenance
ATTENTION!
The compact flash unit must be switched off and disconnected
from the power supply before doing any maintenance work to it.
The compact flash unit
Expert D 500/1000
requires little user
maintenance.
To guarantee the electrical safety, the outside of the unit must
be cleaned regularly from dust and dirt.
Note:
Only clean the unit dry!
Regular maintenance
National safety regulations require the maintenance and ins
-
pection of any electrical system and equipment in regular inter
-
vals. Compact flash units, generators, and accessories must be
inspected at regular intervals to ensure operational safety. An
annual inspection of such equipment ensures the user’s safety
and retains equipment value.
Replacing fuses
ATTENTION!
Fuses must not be „patched up“ or otherwise bypassed. Only
use spare fuses that match the below listed value and have the
response rating ”fast”.
The compact flash unit must be switched off and disconnected
from the power supply before replacing the fuse.
Safety fuses for operation with 300 W
halogen lamp: F 4 A H,
5x20 mm.
Only use fuses with „high switching capacity“, type “H”, accor
-
ding to EN 60127-2/1 or IEC 127-2/1. The wrong safety fuse
can increase the danger of the halogen lamp bursting in case
the coiled filament melts.