Hensel Expert D 1000 Flash Kit User Manual
Page 27
User Manual Expert D 500/1000
27
HENSEL-VISIT GmbH & Co. KG
Â
Set the compact flash unit for the mask on „F“ channels (F1,
F2, F3).
Note:
In this case, the slave of the
Expert D 500/1000
needs to be
switched off with the
SLAVE
key
1
to prevent triggering the first
group of flashes. All other slaves can be switched on.
Â
Set the camera on fastest possible continuous shooting
speed.
Â
Set the number of exposures to „2“ if your camera supports
this.
This guarantees the highest exposure frequency setting with two
consecutive exposures (depending on camera).
The transmitter will trigger the flash group needed for lighting
the motif (C1, C2, and C3) and then trigger the flash group
needed for lighting the mask (F1, F2 und F3).
Currently, all cameras support exposure series speeds from 3
pictures per second to (in theory) 500 exposures per second.
Settings for several work stations
If several separate work stations (up to 3) exist within a radio
range, each work station must have a channel assigned to it.
Â
Set the channel selection switch
F6
on
1
,
2
, or
3.
Â
Assign the same „C“ channel to lighting the motif.
Â
Assign the same “F” channel to lighting the mask.
Example:
station 1: transmitter channel 1 motif C1
mask F1
station 2: transmitter channel 2 motif C2
mask F2
station 3: transmitter channel 3 motif C3
mask F3
Mask lighting
Camera