Heatiator C40 User Manual

Page 25

Advertising
background image

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 25

3. Baffle Removal and Installation

1. Remove all ash from firebox, and extinguish all hot embers

before disposal into a metal container.

2. Remove the baffle protection channel by turning it down

and pulling it out of the firebox. See Figure 4.5

3. Remove ceramic blanket from above the baffle.
4. With a 3/16 in. Allen wrench, remove the front manifold

tube retainer bolt on the air channel under the end of the

front tube. See Figure 4.6.

Figure 4.5 Removing Baffle Protection Channel

Figure 4.6 Removing Manifold Tube

NOTICE: Soak the bolt with penetrating oil for at least 15

minutes before trying to remove it.

5. To remove manifold tube, slide the tube to one side until

one end is out of its hole. Then, while lifting that end of

the fiber board baffle, pull tube up over the air channel

and out of hole at the other end. It is only necessary to

remove the first tube in order to remove the baffle.

6. Slide fiber board baffle forward to front of fireplace and

straight out through door. See Figure 4.7

7. To install the fiber board baffle, repeat steps 2 through 4

in reverse. Be sure the fiber board baffle and ceramic

blanket are pushed back fully and the blanket is down

and flat.

Figure 4.7 Removing Baffle (shown without ceramic blanket)

4. Fan Replacement

Fan Cord Location

The Constitution Fireplace comes standard equipped with

two fans, installed at the factory with electric access on the

right side of fireplace (as you face it).

CAUTION! shock Risk!

Circulating Fireplace Only

• Do NOT remove grounding prong from plug.

• Plug directly into properly grounded three-prong

receptacle.

• Route cord away from appliance.

• Do NOT route cord under or in front of appliance.

CAUTION! shock Risk!
Disconnect power by turning off circuit breaker BEFORE

servicing.

Advertising