1. Fireplace and Hearth Extension are flush on the

floor:

Non-combustible flooring 20 in. (508mm) in front of and 8 in.

(203mm) to either side of the fuel opening with a minimum

thickness of 1 in. (25mm) and (“k” value = 0.49). See Figure

10.1 on page 54 and Figures 10.3, 10.4, and 10.5.

2. Fireplace is installed flush on the floor and Hearth

Extension is raised to the bottom of the fascia:

Raised hearth must be constructed of non-combustible

materials such as cement block or equivalent material. Non-

combustible flooring on the raised hearth

must be 20 in. (508

mm) in front of and 8 in. (203 mm) to either side of the fuel

opening with a minimum thickness of 1 in. (25 mm) and (“k”

value = 0.49). See Figure 10.6.

Figure 10.3 Side View of Factory Built Hearth Extension

The construction of, and materials used for a hearth exten-

sion are shown in Figures 10.1 and 10.3. A hearth extension

of this construction may be covered with any non-combustible

decorative material and may have a maximum thickness as per

Figure 10.2 Seal gaps between the hearth extension and the

front of the fireplace with a bead of non-combustible sealant.

2 in. (51 mm)

required

High temperature

(300°F min.) continuous,

non-combustible sealant

Tile, stone or other

non-combustible material

Floor constructed of wood or

other combustible material

HX3 or HX4

Hearth Ext

or equivalent

insulation

(see Table below)

Fireplace

Protective

Metal Hearth

Strip

Figure 10.2 Hearth Extension Construction

Fascia

Outer Can

Flange

Ember Strip (Seal gap with

High temp, noncombustible

sealant able to withstand

300°)

Tile or

Marble

Minimum 2-1/4 in. (57mm) Cement Board

or equivalent, (or two 1/2 in. pieces)

and "k" value = 0.49. Micore 300

Minimum 20 in. (508mm) in front and

8 in. (203mm) on sides to fuel loading doors

Tile or

Marble

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

Fascia

Outer

Can

Flange

Ember Strip (Seal gap

with high temp,

noncombustible sealant

able to withstand 300°)

Tile or Marble

Minimum 2-1/4 in.

57mm) Cement

Board or equivalent,

(or two 1/2 in. pieces)

and "k" value = 0.49.

Micore 300

Min 20 in. (508mm) in front and 8 in.

(203mm) on sides to fuel loading doors

Combustible

Floor

2 x 4

2 x 4

3/4 in.

(19mm)

Plywood

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

NONCOMBUSTIBLE

DECORATIVE MATERIAL

(2) HX4 MICORE FACTORY

BUILT HEARTH EXTENSION

(Each HX4 = 1/2 in. (13mm) thick)

HEARTH METAL STRIPS

GAP (SEAL WITH NONCOMBUSTIBLE SEALANT)

UP TO BOTTOM OF FASCIA

6 in. (152mm)

1/2 in. (13mm)

Figure 10.4 Fireplace and Hearth Extension Flush on the Floor.

Figure 10.5 Hearth Extension Flush on Floor but on Raised Platform

IMPORTANT! Hearth extension design must be

determined before installation of fireplace.

Raised Hearth Extension Framing

The hearth framing must be constructed of non-combusti-

ble materials (Table 10.2) and placed on an HX3 or HX4,

or equivalent material (Figure 10.2). When creating the

platform, allow for the thickness of the non-combustible

finishing materials (Figure 10.5).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fascia

Outer

Can

Flange

Ember Strip

(Seal gap with

noncombustible

sealant)

Tile or Marble

Minimum 2-1/4 in. (57mm)

Cement Board or equivalent,

(or two 1/2 in. pieces) and

"k" value = 0.49. Micore 300

Min 20 in. (508mm) in front and 8 in.

(203mm) on sides to fuel loading doors

Combustible Floor

2 x 4

2 x 4

3/4 in.

(19mm)

Plywood

Non-combustible

framing materials

Figure 10.6 Raised Hearth Extension to Bottom of Fascia