Heatiator C40 User Manual

Page 41

Advertising
background image

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 41

• Position the Fireplace

This fireplace may be placed on either a combustible or

noncombustible continuous flat surface. Follow the in-

structions for framing in Section 6.C. Slide the fireplace

into position. Be sure to provide the minimum 1 in. air

clearance at the sides and at back of the fireplace as-

sembly. See Section 6.B.

CAUTION! Risk of Cuts/Abrasions. Wear protective

gloves and safety glasses during installation. Sheet metal

edges are sharp.

WARNING! Risk of Fire! Prevent contact with sagging,

loose insulation.

DO NOT install against vapor barriers or exposed

insulation.

• Secure insulation and vapor barriers.

• Provide minimum air space clearances at the sides

and back of the fireplace assembly as outlined in

Section.

WARNING! Risk of Fire! Protective metal hearth strips

MUST be installed on combustible surfaces.

DO NOT

cover metal strips with combustible materials. Sparks or

embers may ignite flooring.

• Refer to Figures 7.4 and 7.5.

• Locate the two protective metal hearth strips measuring

approximately 26 in. x 4 in. (660 mm x 102 mm) included

with this fireplace.

• Slide each metal strip 2 in. (51 mm) under front edge of

fireplace.

• Overlap strips in the middle of fireplace opening by 1 in.

(25 mm) minimum..

• Metal strips must extend beyond the front and sides of

the fireplace opening by at least 2 in. (51 mm).

• Protect the front of a platform elevated above the hearth

extension with metal strips (not included with fireplace)

per Figure 7.5. See

Section 10C for hearth extension

instructions.

Figure 7.4 Position the Protective Metal Hearth Strips

Protective metal strips are placed 2 in.(51mm) under the front of the

fireplace and must extend beyond the front and sides of fireplace

opening by 2 in. (51mm). Nail or screw metal strips in place.

Pallet

Mounting

Brackets

1 in. (25mm) Overlap

Raised Platform

Floor

2 in.

(51 mm)

1 in. (25 mm) min.

overlap

2 in.

(51 mm)

Top piece must overlap

bottom piece

Figure 7.5 Protect the Front of an Elevated Platform

B. Secure the Fireplace

C. Place Protective Metal Hearth Strips