Heatiator C40 User Manual

Page 7

Advertising
background image

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 7

G. Glass Specifications

NOTICE: This installation must conform with local codes. In the

absence of local codes you must comply with the UL127, (UM)

84-HUD and NFPA211 in the U.S.A. and the ULC 610-M87 and

CAN/CSA-B365 Installation Codes in Canada.

EPA Certified:

3.25 grams per hour

Efficiency:

up to 77.8%

BTU Output

with EPA test fuel:

with cord wood:

51,400/ hr.

70,000/hr

Vent Size:

8 inches

Firebox Size:

2.7 cubic feet

Max Wood Length:

24 inches

Fuel:

Cord Wood

Shipping Weight:

650 lbs

WARNING! Risk of Fire! Hearth & Home Technologies

disclaims any responsibility for, and the warranty and

agency listing will be voided by the following actions.

DO NOT:

• install or operate damaged fireplace

• modify fireplace

• install other than as instructed by Hearth & Home

Technologies

• operate the fireplace without fully assembling all

components

• overfire

• install an unvented gas log set

• install any component not approved by Hearth & Home

Technologies

• install parts or components not Listed or approved
Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage. For

assistance or additional information, consult a qualified

installer, service agency or your dealer.

NOTICE: This fireplace is tested and approved as a

decorative fireplace. It should not be factored as a primary

heat source in residential heating calculations.

• Materials which will not ignite and burn, composed of

any combination of the following:

- Steel

- Iron

- Brick

- Tile

- Concrete

- Slate

- Glass

- Plasters

• Materials reported as passing

ASTM E 136, Standard

Test Method for Behavior of Metals, in a Vertical Tube

Furnace at 750° C

• Materials made of or surfaced with any of the following

materials:

- Wood

- Compressed paper

- Plant fibers - Plastic

• Any material that can ignite and burn; flame proofed or

not, plastered or un-plastered

NOTICE: This appliance must be electrically wired

and grounded in accordance with local codes or, in the

absence of local codes, with

National Electric Code ANSI/

NFPA 70-latest edition or the Canadian Electric Code

CSA C22.1.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in

compliance with the applicable electrical codes, when

it is installed in damp locations.

Electrical Codes are used only if the unit is supplied with

a fan.

C. BTU & Efficiency Specifications

F. Electrical Codes

E. Combustible Materials

D. Non-Combustible Materials

This fireplace is equiped with 5mm ceramic glass. Replace

glass only with 5mm ceramic glass. Please contact your

dealer for replacement glass