Heatilator • Constitution EPA Fireplace • 480-1091D

4/20/11

Do not apply combustible finishing materials over any part

of the front of this fireplace.

• The metal fireplace face may only be covered with

noncombustible materials such as ceramic tile, brick,

or stone.

• Do not cover or block any cooling air slots.

The decorative fascia must be removable for future service-

ability of the Automatic Combustion Control.

WARNING

!

Fire Risk!

Comply with all minimum clearances specified.

• A minimum 1 in. (13mm) air clearance must be

maintained at the back and 1 in. (25mm) to the sides of

the fireplace assembly.

• Chimney sections at any level require a 2 in. (51mm)

minimum air space clearance between the framing and

chimney section.

WARNING! Fire Risk!

D. Electrical Access and Wiring Diagram

NOTICE: The manual override switch, rheostat speed con-

trol and cover plate are supplied. You will need to supply:

14-3 wire with ground; 14-2 wire with ground; standard wall

mount junction box; wire nuts.

1. Remove junction box cover plate on the bottom right side

of the fireplace.

2. Thread the 14-3 with ground wire through the opening

with the strain relief on the cover plate.

3. Match colors to wire harness, (red to red, white to white,

etc) and secure with wire nuts.

NOTICE: Wiring for fans must be done before framed

enclosure is completed. If using a Heat Zone kit, it also

must be installed before enclosure is complete.

Figure 6.4 Fan Wiring Diagram

14-2 w/ground

Standard wall mount with

Junction Box

14-3 w/ground

WIRE NUT

WHITE

GREEN

BLACK

BLACK

RED

WHITE

Match colors to wire

harness (red to red,

white to white, etc) and

secure with a wire nut

Incoming Power

(110V)

Power to the Fireplace

Snap Disc

bypass switch

• Maintain clearances.

• Use only non-combustible material below standoffs,

material such as cement board is acceptable.

• Framing or finishing material used on the front of, or

in front of, the appliance closer than the minimums

listed, must be constructed entirely of noncombustible

materials (i.e., steel studs, concrete board, etc.).

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles. DO NOT pack re-

quired air spaces with insulation or other materials.