Heatiator C40 User Manual

Page 43

Advertising
background image

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 43

Vertical distances are measured from the base of the fire-

place as shown in Figure 8.2

To determine the chimney components needed to complete your

particular installation, follow the steps below:
• Determine the total vertical height of the fireplace installation. This

dimension is measured from the base of the fireplace assembly

to the point where the smoke exits the termination cap.

• Subtract the effective height of the fireplace assembly from the

overall height of the fireplace installation (measured from the

base of the fireplace to the bottom of the termination cap, 13 ft.

(4m).

• Refer to Table 8.1 to determine what components must be

selected to complete the fireplace installation.

• Determine the number of ceiling firestops, stabilizers, roof

flashing, etc. required to complete the fireplace installation.

6 ft (1.8 m) max.

unsupported

run

20 ft (6.10 m) max.

pipe between an

offset & return

Ceiling firestop

35 ft (10.7 m)

max. straight

unsupported

chimney height

14.5 ft (4.42 m) min. height/single offset-return

20 ft. (6.10 m) min. height/double offset-return

50 ft (15.24 m) max. height

6 ft (1.83 m) max.

unsupported chimney

above roof

44 in.

(1118 mm)

to top of

standoffs

Figure 8.2 Chimney Requirements

Table 8.1

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

Chimney Stabilizer

SL3

4-3/4

121

Ceiling Firestops

FS338

0

0

FS339

0

0

FS340

0

0

Offsets/Returns

SL315

13-3/8

340

SL330

15-1/2

394

Roof Flashing

RF370

0

0

RF371

0

0

Chimney Sections*

SL306

4-3/4

121

SL312

10-3/4

273

SL318

16-3/4

425

SL324

22-3/4

578

SL336

34-3/4

883

SL348

46-3/4

1187

* Dimensions reflect effective height.

NOTICE: A maximum of two pairs of offsets and returns

may be used.

Minimum overall straight height

13 ft

3.96 m

Minimum height with single offset/

return

14.5 ft

4.42 m

Double offset/return minimum height

20 ft

6.1 m

Maximum height

50 ft

15.24 m

Maximum chimney length between an

offset and return

20 ft

6.1 m

Maximum distance between chimney

stabilizers

35 ft

10.67 m

Maximum unsupported chimney

length between the offset and return

6 ft

1.83 m

Maximum unsupported chimney

height above the fireplace

35 ft

10.67 m

Maximum unsupported chimney

above roof

6 ft

1.83 m

WARNING! Risk of Fire! You must maintain 2 in. (51

mm) air space clearance to insulation and other combus-

tible materials around the chimney system. Failure to do

so may cause overheating and fire.

CAUTION! Risk of Fire and/or Asphyxiation! DO NOT

connect this fireplace to a chimney flue servicing another

appliance.

DO NOT connect to any air distribution duct or

system. These actions could cause overheating/fire in the

chimney flue, or release of exhaust fumes into the living

areas.

NOTICE: You must provide support for the pipe during

construction and check to be sure inadvertent loading has

not dislodged the chimney section from the fireplace or at

any chimney joint.

A. Chimney Requirements

B. Chimney Termination Requirements