Heatilator • Constitution EPA Fireplace • 480-1091D

Page 59

A. Heat Zone Kit (Optional)

This kit is tested and safe when installed in accordance

with this installation manual. It is your responsibility to

read all instructions before starting installation and to

follow these instructions carefully during installations.
Installation of this kit

MUST by performed by a qualified

service technician.
The Heat-Zone-Wood kit is carefully engineered and

must be installed only as specified. If you modify it or

any of its components you will void the warranty and you

may possibly cause a fire hazard. Installation must be

done according to applicable local, state, provincial and/

or national codes.
Plan the location of the fireplace and warm air duct run(s).

DUCT RUN REQUIREMENTS

MAXIMUM Duct Run = 40-ft. (12m)

MINIMUM Duct Run = 36 in. (914mm)

DUCTING MATERIAL

6 in. (152mm) B-Vent Only

DO NOT DUCT into existing furnace plenum

MINIMUM CLEARANCE TO COMBUSTIBLES

1 in. (25mm) from the B-Vent

1/2 in. (13mm) from top & bottom of outlet box

0 in. (0mm) from the sides of outlet box

12 in. (305mm) from wall register to ceiling

(See Figure 11.1).

Caution! ALL wiring should be done by a qualified electrician and

shall be in compliance with local codes and with the National Electric

Code NFPA/NEC No. 70-current. CSC22.1 Canadian Electric Code.

Ceiling Register

Wall Register

Floor Register

Two Duct Kits

Ceiling Register

12 in. (305mm) minimum clearance

from register to ceiling

Possible Air Duct Runs / Locations

Figure 11.1 Minimum Clearances to Combustibles

11