5. Timer Assembly Replacement

1. Remove both doors by lifting doors up and off of

hinges.

2. Remove the black knob and spring handle.
3. Remove the outside air knob and then the 4 screws

from each corner of fascia and remove the fascia.

Place on protected surface.

4. Remove the 3 center bricks from back of fireplace and

all the floor bricks

.

5. Remove 2 Phillips head screws and pry open access

door in the bottom of the fireplace with a flat head

screwdriver. Figure 4.12.

6. Remove 2 screws from cover plate & pull cover plate

toward you. Figures 4.13 & 4.14. Use a flat head

screwdriver to pry the corner edge loose. Pry toward

the fireplace and then press down and out. Figure

4.15

Remove 2 screws

in cover plate

Cover Plate

Pry pointed edge

toward fireplace and

then down and out to

remove.

Cover Plate

Remove 2 screws & pry open door

Spring Handle

Black Knob

Linkage Arm

1/4” bolts

Timer Assemby

Cover Plate

Mechanical

Timer

Figure 4.11 Timer Assembly

Figure 4.12

Figure 4.13

Figure 4.14

Figure 4.15

CAUTION shock Risk!

Disconnect power by turning off circuit breaker BEFORE

servicing.