Heatiator C40 User Manual

Page 45

Advertising
background image

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 45

Figure 8.4 Assembling Chimney Sections

Attach

Flue First

CAK4A

Secure with Screws

Provided

Push Together

Secure to Top

NOTICE: Chimney Air Kit, Part CAK4A is REqUIRED when

using the SL-300 Pipe Series. Detailed instructions are

supplied with the kit.

1. Install the chimney pipe first.

2. Hand bend the tabs in position before placing on the

fireplace.

3. Place the box on top of the fireplace around the chimney

pipe, push both pieces together and secure with screws

provided.

4. Use the pre-punched holes in the tabs as guides and

drill holes through the fireplace top.

5. Secure the CAK4A in place.

6. Seal around the kit at the flue and at the top of the can

with caulk.

NOTES:

1. The outside termination cap must be a minimum of 6 ft

(1829 mm) above the ground and kept free of debris.

2. If the CAK4A is installed in a chase, the CAK4A side

termination cap must be at least 3 ft (914 mm) below

the chimney top.

3. Seal around the cap and flex with caulk to stop air from

getting in to the chase (See Figures 9.4-9.8 on page

52).

Figure 8.5 Installing the CAK4A

NOTICE: Chimney sections cannot be disassembled once

locked together. Plan ahead!

• Lock chimney sections and/or offsets/returns together

by pushing downward until the top section meets the

stop bead on the lower section.

• Pull on the top section to make sure it is fully engaged

and will not separate.

• You may use #6 or #8 sheet metal screws no longer

than 1/2 in. (13 mm) to fasten chimney sections

together. Do NOT penetrate inner flue.

WARNING! Risk of Fire! You MUST use screws (provid-

ed) to fasten offset/returns to chimney sections to keep

the chimney parts from twisting. Failure to do so could

cause fire.

• Fasten offset/returns to chimney sections. Insert the

screws (provided) through the predrilled holes. Do NOT

penetrate inner flue.

• Secure chimney returns with hanger straps provided;

fasten to studs or joists.

• Vertical straight runs of chimney must be supported

every 35 ft (10.7 m).

WARNING! Fire Risk!

The flex hose must never be compressed or deformed!

Use only those components described in this manual.

Substitute or damaged chimney components could impair

safe operation and cause overheating and fire.

Attach either a straight chimney section or an offset to the

top of the fireplace (depending on your installation require-

ment). Chimney sections are locked together by pushing

downward until the top section meets the stop bead on the

lower section.
The inner flue is placed to the inside of the flue section be-

low it. The outer casing is placed outside the outer casing

of the chimney section below it. See Figure 8.4.

WARNING! Risk of Fire! DO NOT install substitute or dam-

aged chimney components.

D. Assemble the Chimney Sections

E. Installing CAK4A and Flex Pipe