E. finishing material, D. position the hearth extension – Heatiator C40 User Manual

Page 56

Advertising
background image

Page 56

Heatilator • Constitution EPA Fireplace • 480-1091D

4/20/11

Position and secure the hearth extension over the protective

metal strips that have been placed partially under the fireplace

front. These strips should be protruding approximately 2 in.

(51 mm) from under the fireplace front and 2 in. (51 mm) on

both sides of the fireplace opening. See Figure 10.7.
Seal the crack between the hearth extension and fireplace

with a bead of non-combustible sealant.

See Figure 10.8.

Apply a non-combustible finishing material of your choice to

the hearth extension.

NOTICE:

see pages 36-37 and 55, “clearances to combus-

tibles, hearth extensions / floor protection” for clearances

required for different hearth extension installations. The

clearances must be strictly adhered to.

Warning! Fire Risk!

Hearth extensions are to be installed only as illustrated

to prevent high tempertures from occurring on concealed

combustible materials.

Hearth sealing strips prevent burning or hot particles from

inadvertently falling directly on combustible surfaces in the

event the building should settle and disturb the original

construction.

Figure 10.7 Positioning the Protective Metal Hearth Strips

Seal with

non-combustible

sealant

Figure 10.8 Position the Hearth Extension

Protective metal strips are placed 2 in.(51mm) under the front of the

fireplace and must extend beyond the front and sides of fireplace

opening by 2 in. (51mm). Nail or screw metal strips in place.

Pallet

Mounting

Brackets

1 in. (25mm) Overlap

E. Finishing Material

WARNING

!

Do not install combustible materials over the

metal fireplace face of the fireplace! This poses a safety

hazard and may start a fire.
You may only use noncombustible material over the metal

face of the fireplace.
NOTICE: The decorative fascia must be removable for future

serviceability of the Automatic Combustion Control.

• Combustible Material

Materials made of or surfaced with wood, compressed

paper, plant fibers, plastics, or other materials that can

ignite and burn, whether flame proofed or not, or whether

plastered or un-plastered shall be considered combus-

tible materials.

• Non-Combustible Material

Materials which will not ignite and burn. Such materials

are those consisting entirely of steel, iron, brick, tile, con-

crete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials, in a Ver-

tical Tube Furnace at 750°C, shall be considered non-

combustible materials.

D. Position the Hearth Extension