tinue to flash. The dialer will

continue to dial until all numbers

have been dialed.

ALARM CANCEL

At any time, you can silence

your alarm system by pressing the

SECURITY-OFF key and entering your

code. If the system has reported,

or is in the process of reporting

an alarm to a central station, it
will send the alarm code followed

by a code indicating that the alarm

has been canceled by the user.

If an alarm is canceled before

the dial out delay has expired, the

system will not report any alarm.

If an alarm is canceled during a

voice dial out, the system hangs up
immediately, unless the recipient

of the call has entered a master or

access code.

TROUBLE INDICATIONS

The Model 1503 constantly moni-

tors the alarm loops and several
internal matters and will alert you

if it detects trouble. The particu-

lar trouble is indicated on the

bottom line of the display and a

trouble signal is given by beeping
the console beeper continuously, 2

beeps per second.

When any trouble condition oc-

curs, the console will beep twice
per second and continue to beep

until the CANCEL button is pressed

to acknowledge the trouble. The

console will say TRBL NOW (trouble

now) if the trouble condition actu-
ally exists while you are looking

at the console. It will say HAD

TRBL (had trouble) if the trouble

condition occurred and then cor-

rected itself.

The trouble indications and

their meanings are shown below.

- ZONE NAME TRBL NOW or HAD TRBL:

If the reading for a zone be-

comes abnormal, trouble will be

indicated on that zone. See SHOW

TEST. Trouble in zones is usu-

ally caused by excessive resis-
tance in the contact and wiring.

If the cause is not obvious,

call your installer for service.

- AC POWER OFF TRBL NOW or HAD

TRBL: Indicated if the normal

house current powering the Model

1503 Control/Communicator is

interrupted for more than 3 min-

utes. If this happens without
good cause, check the black wall

mounted transformer to ensure

that it hasn’t come out of the

wall socket; check to see that

the socket has power; check the
fuse on the Model 1503 Termina-

tion Board in the Model 1503

Control/Communicator to be sure

that it is good.

- BATTERY LOW TRBL NOW or HAD

TRBL: Every hour, the Model 1503

makes a dynamic test of the bat-

tery. The charger is turned off

and a load is placed on the bat-
tery for 10 seconds, then the

battery voltage is read. If the

battery voltage is too low, then

the console will indicate BAT-

TERY LOW. If this happens, make
sure that the battery is con-