Home Automation 1503 User Manual

Page 48

Advertising
background image

46

Home Automation, Inc.

(like a programmable thermostat),

and by buttons - for example, your

mode of security. Therefore, your

temperatures are adjusted for your
real-life schedule for maximum

comfort and energy savings.

Following is a programming ex-

ample for temperature control based
on security modes and button 1,

which we call “Vacation”.

Programs for “when security

off:”

- PROG, *, 175 (when security

off), ENTER: UNIT-NUMBER, 17,

OFF. (Turns energy saver off

when you disarm security so your
thermostat works normally.

- *, 175, ENTER: UNIT-NUMBER, 17,

*(lo temp) 65. (Sets winter set-

back temperature.)

- *, 175, ENTER: UNIT-NUMBER, 17,

#(hi temp) 85. (Sets summer set-

back temperature.)

Programs for “when asleep:”

- *, 177, ENTER: UNIT-NUMBER, 17,

ON. (Turns on energy saver when

asleep.)

Programs for “when away:”

- *, 178, ENTER: UNIT-NUMBER, 17,

ON. (Turns on energy saver when
away.)

Programs for “Vacation:”

- *, 1, ENTER: UNIT-NUMBER, 17, *,

50. (Sets vacation mode winter

setback)

- *, 1, ENTER: UNIT-NUMBER, 17, #,

86. (Sets vacation mode summer

setback)

- *, 1, ENTER: AWAY, master code.

(Arms security and turns on en-

ergy saver when you go into va-

cation mode).

You may wish to add timed com-

mands to change the setback tem-

peratures and on/off status of the

energy saver modules to complete

your control strategy.

USING TEMPERATURES TO CONTROL
APPLIANCES

It is possible to set high and

low setpoints on all temperature

zone types. The temperature zone

types are:

- Programmable energy saver module

(PESM) (Type 80)

- Outdoor temperature (Type 81)

- Temperature (Type 82)
- Temperature alarm (Type 83)

The setpoints are set as de-

scribed for programmable energy

saver modules. The zone type is set
up during installation by your

dealer.

Each of the setpoints may be set

from 0 to 120 degrees. Setting a
setpoint to 0 degrees disables that

setpoint. The high setpoint must

always be at least four degrees

higher than the low setpoint if

both setpoints are used.

Advertising