The TIME that was entered before

setting an on or off time to NEVER

is saved, and will re-appear when a

day is set in place of NEVER.

Setting both the DIAL OUT 1 ON

and the DIAL OUT 1 OFF times to

NEVER will make DIAL OUT NUMBER 1

never active.

DIAL OUT NUMBER 2

DIAL OUT 2 ON

DIAL OUT 2 OFF

DIAL OUT NUMBER 2 can entered

into the system and set for time

and dates exactly like DIAL OUT
NUMBER 1.

The default for DIAL OUT 2 ON is

12:00 AM MTWTFSS, and the default

for DIAL OUT 2 OFF is NEVER, so
that DIAL OUT NUMBER 2 is always

active.

DIAL OUT NUMBER 3

DIAL OUT 3 ON

DIAL OUT 3 OFF

Same as DIAL OUT NUMBER 2.

DIAL OUT NUMBER 4

DIAL OUT 4 ON

DIAL OUT 4 OFF

Same as DIAL OUT NUMBER 2.

10. UNDERWRITER'S
L A B O R A T O R I E S
R E Q U I R E M E N T S

The Model 1503 Version 2, Model

1503-LC, Model 1102 Expansion En-

closure and Model 1503A2005 con-

soles have been tested and Listed
by UL for these applications:

- UL 985, Household Fire Warning

System Units

- UL 1023, Household Burglar Alarm

System Units

- UL 1635, Digital Burglar Alarm

Communicator System Units

- UL 1637, Home Health Care Sig-

naling Equipment

When used in a UL Listed Instal-

lation, the following items apply:

1.

The “High Security Mode” must

be ON.

2.

The “Enable Auto Bypass” fea-

ture must be OFF.

3.

The ENTRY DELAY shall not

exceed 45 seconds.

4.

The EXIT DELAY shall not ex-

ceed 60 seconds.

5.

Double Delay and Quad Delay

zone types shall not be used.

6.

Underwriter's Laboratories

requires the sounding device to

be mounted indoors. If, however,

the sounding device is connected

to the "EXT HORN" terminals of

the Model 1503, then the OUTSIDE
SIREN DELAY shall be set to 0.