Home Automation 1503 User Manual

Page 29

Advertising
background image

27

Model 1503 Owner's

Manual

The output may be turned ON for 1-

99 minutes, then OFF; or turned OFF

for 1-99 minutes then ON.

To enter a timed on/off command, press

the UNIT-NUMBER key, enter the unit
number (or scroll to it using the SHOW

and SETUP keys), press the TIME key,
enter the on/off time in minutes, then
press the ON or OFF key.

For example, to turn unit 11 on for 10

minutes then off, press UNIT-NUMBER,
11, TIME, 10, ON.

To turn unit 3 off for 30 minutes then
on, press UNIT-NUMBER, 3, TIME, 30,

OFF.

MOMENTARY ON/OFF COMMANDS

A special variant of the timed

on/off command allows you to pulse

an output on or off for three sec-

onds. This feature can be useful
for operating low voltage control

systems (drapery motors, lighting

controls, etc.)

Enter an on or off time of 0 to get a 3
second output. For example, To turn a

unit 2 on for 3 seconds then off, press
UNIT-NUMBER, 2, TIME, 0, ON.

TEMPERATURE CONTROL

Your Model 1503 can control tem-

peratures of your heating and cool-

ing system, monitor the outside

temperature and detect high and low
temperatures in special situations.

Other appliances can be controlled

by temperature as well - such as a

bathroom heater or a ceiling fan.

Temperature control starts with

unit number 17. If you have two

heating and cooling systems, they

are usually unit numbers 17 and 18.

Your dealer will explain your par-

ticular installation.

MODEL 1101 PROGRAMMABLE ENERGY
SAVER MODULE

The Model 1101 Programmable En-

ergy Saver Module (PESM) provides

energy savings and convenience by

setting the HVAC system(s) to the

proper temperature based on whether
you are home, asleep, or away. It

can be controlled over the tele-

phone, and the temperature of the

home can be reported over the

phone. A freeze alarm feature will
cause a dial out if the temperature

falls below a preset level. (The

Model 1101 PESM has not been inves-

tigated by Underwriter's Laborato-

ries.)

The Model 1101 PESM is a tem-

perature sensor and control relay

in a small enclosure that mounts

near your central heating, ventila-
tion, and air conditioning (HVAC)

system thermostat. The PESM allows

the Model 1503 to read the tempera-

ture of the area that the HVAC

system controls. When you are away
from your home or asleep, the PESM

can be set to allow the temperature

to drift higher or lower to reduce

the operating time of the HVAC

system, hence saving energy dol-
lars.

The PESM provides an energy

saver function. When the energy

saver is on, the HVAC system is set
back, meaning that the temperature

is allowed to rise or fall to an

energy saving level. When the en-

ergy saver is off, your thermostat

operates normally. Your thermostat

Advertising