Home Automation 1503 User Manual

Page 23

Advertising
background image

21

Model 1503 Owner's Manual

nected and that the battery fuse

(in line with the red wire con-

nected to the battery in the

Model 1503 Control/Communicator)
is good. The BATTERY LOW indica-

tion will remain until the next

battery test is run, 1 hour

later, or when a SHOW TEST com-

mand is given.

- COMMUNICATOR TRBL NOW: Indi-

cated if the digital communica-

tor (not the voice dialer) was

unable to make contact with the
Central Station after trying

both numbers multiple times.

This indication will remain un-

til the digital communicator

tries again (as a result of a
reportable alarm or event occur-

ring) or until both phone num-

bers are removed from the digi-

tal communicator. If this hap-

pens, there could be a problem
with the system, central sta-

tion, phone line or the wrong

phone numbers have been entered

in the digital communicator.

Call your dealer for service.

- DEVICE FUSE TRBL NOW or HAD

TRBL: Indicated if there is a

problem with one (or more) of

three solid state fuses on the
Model 1503 Processor Module.

These fuses can be restored

without having to replace anything.

They can be seen by opening the
Model 1503 Control/Communicator

enclosure door and looking in the

opening of the aluminum cover on

the door. At the bottom you will

see three small round components
labeled PTC1, PTC2 and PTC3.

The three fuses are for (from

left to right) the CONSOLES, the

DEVICES and the HORNS.

The CONSOLES

are powered through the fuse la-
beled CONSOLES. If the CONSOLES

fuse is “blown”, then the consoles

will not be working. The DEVICES

fuse powers the following devices

that may be connected to the system
(some are options:)

- motion detectors

- smoke/fire detectors

- AUXiliary OUTputs (energy saver

relays)

- COMMUNICATOR outputs

- OK TO ARM output

- ARMED output

The HORNS fuse powers the Inte-

rior siren and the Outdoor Siren.
If it is hot, there is a fault in

the wiring to one of these devices.

To reset these fuses, the fault

must be cleared. Then, unplug the
Model 1503 power transformer (or

remove the tube type fuse on the

Termination Board.) Disconnect,

then immediately reconnect the

battery (within 10 seconds to re-
tain your home control programs.)

Wait a minute or two for the PTC

fuse to cool. Then plug in the

transformer. If you do not feel

competent performing such tasks,
call your dealer for service.

NOTE: If the battery is discon-

nected or the battery fuse is blown

you will get a DEVICE FUSE TROUBLE
indication AND a BATTERY LOW indi-

cation when the battery test oc-

curs.

- PHONE LINE DEAD TRBL NOW or HAD

TRBL will be indicated if the

phone line is dead for more than

1 minute. If this happens, check

Advertising