Buttons can be programmed to run

on a time and date or day schedule

exactly as any other command. But-

tons can be programmed as one-time
programs or repeating programs.

EXAMPLE: Program BUTTON 2 to run at

6:00 PM every weekday,

Press PROG (from the time, date and

status display)

Press 2, ENTER. (The button number that
you wish to program)

The display will read “RUN BUT-

TON 2: 12:00 AM 11/08 *IF”.

Press TIME, 6, 0, 0, PM.

Press DATE-DAY, DATE-DAY, 8, ENTER.

The display will now read “RUN

BUTTON 2: 6:00 PM MTWTF— *IF”. If
a name has been set up for button

2, the display will show the name

instead of BUTTON 2.

Press ENTER to commit the program to
memory, or CANCEL to quit.

If this program is entered, the

Model 1503 will run all of the
BUTTON 2 programs every weekday at

6:00 PM.

To program other buttons, simply

substitute the desired button num-
ber in the above example.

ZONE ACTIVATED BUTTONS

Every security zone on the Model

1503 can be used to trigger home

control events. For example, the

burglar alarm contact on the front
door can turn on the front foyer

light and upstairs hallway light

when the door is opened, if it’s

dark outside.

Another example is that a motion

detector can be used to turn a

light in a hallway on for 5 min-

utes, then automatically turn it
off.

This feature is implemented us-

ing BUTTONs. Every security zone

automatically activates one button
when the zone is opened, or in

alarm, and another button when the

zone is closed, or secure. For

example, when zone 1 is opened, the

programs for BUTTON 11 are ex-
ecuted. When zone 1 is closed, the

programs for BUTTON 10 are ex-

ecuted. The button programs are

activated regardless of the zone

type and whether or not the secu-
rity system is armed.

Programs for zone activated but-

tons are only run once, when the

transition takes place.

Other Buttons are automatically

activated when the fire, police, or

medical emergency alarms are acti-

vated.

Table 1 in the appendix shows

which buttons are activated for

each zone.

EXAMPLE 2: Program the stairwell

light (unit 5) on for 5 minutes

when the stairwell motion detector

(zone 6) is activated. From Table

1, we determine that the zone 6
activates button 21 when it goes

Advertising