92

4.3 Replacing the Pad ASSY

5. Attach a new Pad ASSY to the Guide plate.

6. Install the guide plate in the reverse order of the removal. You should push it down

then the installation can be done smoothly.

7. Lower the ADF upper sheet guide gently.

8. Lift the Upper transport unit a little to release the safety lock and then lower the

transport unit slowly.

9. Clear the Pad counter.

Please refer to the section “7.3 Setup Mode Details”, “9. Abrasion counter reset.”

ATTENTION

Confirm that the pad is firmly attached to the
guide.

If not attached firmly, paper feed errors such as
document jams may happen.